Sump Pump Battery Backup Calculator
Sump pumps fail exactly when power fails, which is exactly when water arrives. Enter your pump and your storm, and see whether your battery survives it. Background reading: sewage backup and sanitation.
Your setup
A common 1/3 HP sump pump draws about 800W while running. Check your label.
Backup verdict
- Average draw
- 67W (8.3% duty)
- Usable energy
- 450 Wh
- Runtime
- 6.8 hours
- 12-hour storm
- Short by 5.2 hrs
- Step up to
- about 75Ah (AGM)
Close the gap
- PumpSpy 75Ah sump battery — purpose-built terminals for backup systems
- Liberty SumpJet water-powered backup — for outages no battery outlasts
- MOTOPOWER trickle charger — a backup battery is dead weight unless kept charged
Sump backup questions
How long will a 75Ah battery run my sump pump?
A 75Ah 12V AGM battery holds about 450 usable watt-hours. A 800W pump cycling 5 minutes per hour draws about 67W on average, so about 6 to 7 hours. Enter your pump watts and cycle rate above for your exact number.
Can a portable power station run a sump pump?
Sometimes, but it is the wrong tool for most pumps. Sump motors draw a large surge at startup, far above their running watts, and most mid-size stations fault on it. A 12V battery backup sized by this calculator is purpose-built for the job. Use a station for the fridge and phones, and give the pump its own battery.
AGM or LiFePO4 for sump backup?
LiFePO4 gives about 70% more usable energy per rated amp-hour (85% depth of discharge vs 50%) and lasts far more cycles. AGM costs less upfront. For a pump that runs rarely but must work, LiFePO4 is the better buy if the budget allows.
What if outages outlast any battery?
Then a battery is the wrong layer. A water-powered backup pump moves water on municipal pressure with no electricity at all. Match the backup to how your power usually fails: short outage, battery; long outage, water-powered or generator.
How this is calculated
Runtime = usable Wh / average watts. Average watts = running watts x duty cycle (cycles/hr x seconds/cycle / 3600). Usable Wh = amp-hours x 12V x 0.5 for AGM or x 0.85 for LiFePO4. Your pump label and your storm are the only honest inputs.